| Wind speed |
|
Wind direction |
Range
Accuracy
Resolution |
0 - 70 m/s
± (0,5 m/s + 5%)
1/16 (0,0625 m/s)
|
|
Azimuth
Accuracy
Resolution |
0 - 360°
± 5°
1/16 (0,0625°) |
| Air temperature |
|
Relative humidity |
Range
Accuracy
Resolution |
- 40°C - +60°C
± 1°C
1/16 (0,0625°C) |
|
Range
Accuracy
Resolution |
0% - 100%
± 4 % (0-20% // 90-100%)
± 3 % (20—90%)
1/16 (0,0625 %) |
| Absolute atmospheric pressure |
|
Dew point calculation |
Range
Accuracy
Resolution |
300 - 1100 hPa (mbar)
± 1 hPa @ 23°C
± 3 hPa @ -40—+60°C
1/16 (0,0625 hPa) |
|
|
Yes |
| Connection for external instrument |
|
Start up |
Analogique
Digitale
|
1
1 |
|
|
< 20 s |
| Data transmission |
|
Autotest |
| |
Serial link RS-485, half duplex |
|
|
Permanent |
| Input voltage |
|
Consumption |
| |
24 - 48 V DC |
|
|
15 W electronic
325W Heating system
|
| Operating temperature |
|
Storage temperature |
| |
- 40°C - + 60°C |
|
|
- 55°C - + 70°C |
| Size |
|
Options |
Height
Diameter
Weight |
292 mm (11.4 inches)
120 mm (4.72 inches)
1.3 kg (2.86 lbs) |
|
External cnverter RS485 <=>TCP-IP
Software for acquisition and graphic representation |
| Colour |
|
|
|
Aluminium
According to customer's color against additional price
|
|
|
|